Laserfiche WebLink
W A T E R E N E R G Y L I F E <br />RIVERSIDE PUBLIC UTILITIES <br />Board Memorandum <br />P U B L I C U T I L I T I E S <br />BOARD OF PUBLIC UTILITIES DATE: JULY 11, 2016 <br />ITEM NO: 7 <br />SUBJECT: PLANNED ROUTINE ELECTRIC AND WATER CAPITAL PROJECTS OVER $500,000 <br />IN FISCAL YEAR 2016/17 FOR $19,150,000 <br />ISSUE: <br />The issue for Board of Public Utilities consideration is to receive a report highlighting capital improvement <br />projects over $500,000 planned for Electric and Water in fiscal year 2016/17 with a combined total budget <br />of $ 19,150,000. <br />RECOMMENDATION: <br />That the Board of Public Utilities receive this report highlighting planned Electric and Water capital <br />improvement projects over $500,000 for a combined total of $ 19,150,000 in fiscal year 2016/17. <br />BACKGROUND: <br />On March 14, 2016 the Board of Public Utilities (Board) voted to recommend that the City Council approve <br />the Electric and Water annual Capital Improvement Program (CIP) budget funds for fiscal year (FY) <br />2016/17, including a capital outlay of $34.9 million for the electric system and $26.5 million for the water <br />system. The City Council approved the annual budget for FY 2016/17 at their meeting on June 21, 2016. <br />The purpose of this report, is to provide the Board an overview of the routine infrastructure projects over <br />$500,000 planned for FY 2016/17, and to highlight the importance of these projects. Discussion of these <br />projects at the beginning of the fiscal year will provide context and familiarity to streamline Board approval <br />of individual project actions throughout the fiscal year. <br />The projects to be presented and discussed include the following: <br />No. <br />Electric <br />Budget <br />E1 <br />Replacement of 200 Poles and Repair of 5 Underground Vaults (various <br />locations) <br />$1,900,000 <br />E2 <br />Substation High Voltage 69kV (kilo -Volt) Circuit Breaker Replacement (two <br />locations) <br />$1,700,000 <br />E3 <br />Harvey Lynn Substation Switchgear Upgrade <br />$4,400,000 <br />E4 <br />Underground Cable Replacement (Canyon Crest Area) <br />$1,500,000 <br />E5 <br />Plaza Substation 4 -12kV (kilo -Volt) Conversion <br />$2,800,000 <br />E6 <br />Oran gecrest- Freeman Substation Fiber Upgrade <br />$1,400,000 <br />E1 — Replacement of 200 Poles and 5 Underground Vaults (various locations) <br />Detailed inspections identify poles and underground vaults which are at risk of failure and have the <br />potential of becoming a public safety hazard or adversely affecting the electric system's reliability. This <br />project addresses the replacement of 200 existing wood poles and repair of 5 underground vaults in various <br />locations based upon the results of inspections. <br />